Impedance Matching and Isolation Transformer

  • Designed for use in line matching and isolation circuits
  • Ideal for use as baluns or as isolation transformers
  • Use in popular networks such as Ethernet or 10 Base T and 100 Base T
  • Use in proprietary networks based on RS232, RS422 or RS485
  • Products are available to support data rates from 9.6Kb/sec. to 250Mb/sec.

ELECTRICAL CHARACTERISTICS @ 25˚C

BH PART NUMBER ET CONSTANT (V uSEC. MIN.) TURNS RATIO PRIMARY INDUCTANCE ISOLATION VOLTAGE SCHEMATIC PACKAGE STYLE DIM. “A” MAX. DIM. “B” MAX.
500-1430 40 1:1:27 2.8mH 500 VDC 6 6 0.37 0.32
L00-1455 100 1:1 21mH 1500 VRMS 3 1 0.4 0.35
500-1461 1200 1:1 800mH 2200 VRMS 4 1 0.57 0.4
500-1463 0 1:1 140uH 1200 VAC 4 3 0.54 0.31
500-1465 380 1CT: 1CT 193mH 1500 VRMS 2 1 0.45 0.43
500-1438 3 1CT: 1CT 150 H 500 VDC 5 2 N/A N/A
500-1542 900 1CT: 1CT 430MH 2900VDC 2 1 0.56 0.39
500-1544 90 1: 1CT 2.2mH 1000 VRMS 1 1 0.6 0.35
500-2279 1.5 1: 1 TAPPED 100 uH 2500 VAC 5 4 N/A N/A
500-2387 14 1:1.22 TAPPED 1.0mH 1500 VAC 6 5 N/A N/A
500-3177 NA NA 205 uH 500 VAC See pdf See pdf See pdf See pdf
500-3187 2.1 1:1 100uH 500 VRMS 200°C See pdf See pdf
L00-1488 25 1: 1CT 2.2mH 1000 VRMS 1 1 See pdf See pdf
L00-3360 45 1:1:1 3.3mH See pdf See pdf See pdf See pdf See pdf
  • Note: Part numbers beginning with “L” are RoHS compliant.
Impedance Matching Transformers Schematics Impedance Matching Transformers Mechanics
© 2024 BH Electronics
12219 Wood Lake Drive Burnsville, MN 55337
Phone: 952-894-9590
Fax: 952-894-9380